Parallel Condensing Units
KLB2/KLB3 Series Bitzer Piston Parallel Condensing Units
Parallel condensing units with two (B2) or three (B3) BITZER semi-hermetic piston compressors on one rack, for large cold rooms and multi-room projects. Medium/high 12.5°C to -25°C and medium/low -5°C to -40°C versions. R22/R404A, 380V/3P/50Hz.
Specifications
- Compressors
- Two (B2) or three (B3) BITZER semi-hermetic piston compressors, original German
- Series
- KLB2PH/KLB3PH medium/high; KLB2PL/KLB3PL medium/low
- Evaporating temperature
- 12.5°C to -25°C (PH); -5°C to -40°C (PL)
- Refrigerant
- R22 / R404A (Y models: R404A)
- Power supply
- 380V / 3-phase / 50Hz
- Model range
- 4TES-12(Y) to 6FE-50(Y) per compressor set
- Cooling capacity, B2 4TES-12 at 0°C, R22
- 69,400 W (catalog sample data)
- Cooling capacity, B2 6FE-50 at 0°C, R22
- 249,200 W (catalog sample data)
- Cooling capacity, B3 6FE-50 at 0°C, R22
- 373,800 W (catalog sample data)
- Cooling capacity, B2PL 4TES-9 at -15°C, R22
- 56,250 W (catalog sample data)
- Scaling
- B2 about 2× and B3 about 3× the matching single unit (from the catalog tables)
- Application
- Large cold storage, multi-room cold stores, food processing plants, distribution centres
The KLB2/KLB3 series is COOLEST's parallel condensing unit: two (B2) or three (B3) original German BITZER semi-hermetic piston compressors on one rack, for loads too large for a single unit. Medium/high versions cover 12.5°C to -25°C and medium/low versions -5°C to -40°C, on R22 or R404A at 380V/3P/50Hz. If one room — or several rooms — needs more cooling than the largest single piston unit can give, start here.
Who the parallel rack fits, and who should look elsewhere
The parallel rack exists for one reason: scale. The largest single piston unit in the catalog tops out at 124,600 W at 0°C on R22. A large cold store, a food-processing plant, or several rooms served from one plant room can need two or three times that. The parallel rack answers by putting two or three compressors on a common rack and sizing the whole thing as one unit. The smallest B2 set, the 4TES-12, delivers 69,400 W at 0°C on R22 (catalog sample data); the largest B2, the 6FE-50, delivers 249,200 W; and the largest B3, the 6FE-50, delivers 373,800 W. The arithmetic is visible in the tables: a B2 set gives about twice the matching single unit, and a B3 about three times — the 4TES-12 single is 34,700 W, the B2 is 69,400 W, the B3 is 104,100 W.
Two buyers should not start here. If a single unit covers the load — anything up to the KLPH or KLPL range — a single unit is simpler to install, simpler to maintain, and simpler to replace. And if the job is one small room, the parallel rack is the wrong scale entirely. The rack is for large loads and multi-room plants; buy the scale the load actually needs.
What is inside, and how the numbers map to the job
Each compressor on the rack is the same original German BITZER semi-hermetic piston machine as the single units, with accessories imported or from well-known domestic brands. The rack is offered in the same two temperature families as the single units: the PH sets cover 12.5°C to -25°C for medium/high-temperature rooms, and the PL sets cover -5°C to -40°C for frozen rooms. The same model can run on R22 or R404A — Y models are the R404A versions — and power is 380V/3P/50Hz across the series. The model range runs from 4TES-12(Y) to 6FE-50(Y) per compressor set, so the buyer picks the compressor size and the rack size together.
What the catalog tables show, and what this page does not go beyond, is the capacity of each set at each evaporating temperature. The low-temperature side is covered too: the B2PL 4TES-9 delivers 56,250 W at -15°C on R22 (catalog sample data). Treat all capacity figures as what they are: catalog sample data for reference. The exact specification of the rack you buy — including the rack dimensions and the control arrangement, which the catalog tables do not list — is fixed in the contract, not in the catalog.
How to order
Ordering a parallel rack comes down to five inputs. First, the total cooling load — or the rooms, their sizes, what goes in them, and the target temperatures. Second, the evaporating temperature for each room, since a rack serving rooms at different temperatures is a different design question. Third, the refrigerant: R22 or R404A. Fourth, the power supply on site. Fifth, how many compressors: two or three. With those five, we match the set and confirm the final specification in the contract.
To start, send your total load, the room temperatures and the number of rooms through the inquiry form. Yiwu Ruluan Trading will come back with the matching parallel set and a quotation. No prices, lead times or certifications are listed on this page because the catalog does not give them; they are confirmed case by case, in writing, before you order.