COOLEST KLPH air-cooled condensing unit with BITZER semi-hermetic piston compressor
COOLEST water-cooled condensing unit with BITZER piston compressor
Two-Stage Condensing Units

KLDPL Series Single-Machine Two-Stage Piston Condensing Unit

Single-machine two-stage condensing unit on the BITZER semi-hermetic piston compressor, for deep low-temperature rooms from -20°C to -50°C. Air-cooled (FL) and water-cooled (SL) versions. R22/R404A, 380V/3P/50Hz, models S4T-5.2 to S6F-30.2.

Specifications

Compressor
BITZER semi-hermetic two-stage piston compressor, original German
Series
KLDPL, single-machine two-stage
Evaporating temperature
-20°C to -50°C (-4°F to -58°F)
Refrigerant
R22 / R404A (Y models: R404A)
Power supply
380V / 3-phase / 50Hz
Model range
S4T-5.2(Y) to S6F-30.2(Y), air-cooled FL and water-cooled SL
Cooling capacity, S4T-5.2 at -40°C, R22
4,100 W (catalog sample data)
Cooling capacity, S6F-30.2 at -40°C, R22
21,350 W (catalog sample data)
Cooling capacity, S4T-5.2 at -25°C, R22
7,880 W (catalog sample data)
Fan, S4T-5.2 air-cooled
FN48, Φ500 × 1, 6,250 m³/h, 420 W
Water-cooled condenser, S4T-5.2
LC05, water flow 2.7 m³/h
Application
Blast freezing, deep-frozen storage, -40°C to -50°C rooms
The KLDPL series is COOLEST's single-machine two-stage condensing unit built on the BITZER semi-hermetic piston compressor, for deep low-temperature rooms from -20°C down to -50°C. It comes in air-cooled (FL) and water-cooled (SL) versions, runs on R22 or R404A at 380V/3P/50Hz, with models from S4T-5.2 to S6F-30.2. If your room must hold -40°C or below — blast freezing, deep-frozen storage — start here.
Who the two-stage unit fits, and who should look elsewhere The KLDPL exists for the coldest rooms in the catalog. The single-stage piston series stops at -40°C with the KLPL; the two-stage KLDPL continues to -50°C. Blast freezers, deep-frozen storage and rooms that must hold -40°C or below are its jobs. The smallest model, the S4T-5.2, delivers 4,100 W at -40°C on R22 (catalog sample data), and the range runs up to the S6F-30.2 at 21,350 W at the same temperature — small numbers next to the medium-temperature series, because deep cold is hard work and the capacity at -40°C is a fraction of the capacity at 0°C. That is normal for this temperature, and it is why the load must be calculated at the actual room temperature, not borrowed from a warmer one. Two buyers should not start here. If the room holds -25°C or warmer, the KLPH series covers it with a simpler single-stage machine. If the room holds -40°C and no colder, the KLPL single-stage series covers it — the two-stage machine is for rooms that go below -40°C or that need the margin a two-stage design gives at the bottom of the range. And if the load is large at deep temperatures, the HSN screw series runs to -45°C at a much larger scale. The KLDPL is the deep-cold answer at piston scale.
What is inside, and how the numbers map to the job The machine is a single two-stage piston compressor: one BITZER semi-hermetic compressor doing the work in two stages, on the same piston platform as the rest of the series. It is offered in both cooling methods — air-cooled FL versions with their own fans, and water-cooled SL versions with LC shell-and-tube condensers — so the same deep-cold job can be served on an open site or in a sealed plant room. The air-cooled S4T-5.2 runs an FN48 fan, Φ500 × 1, moving 6,250 m³/h at 420 W; the water-cooled S4T-5.2 uses an LC05 condenser with a water flow of 2.7 m³/h. Power is 380V/3P/50Hz and the refrigerant is R22 or R404A — Y models are the R404A versions — across the series. The capacity table tells the story of deep cold plainly: the S4T-5.2 gives 7,880 W at -25°C and 4,100 W at -40°C on R22, both catalog sample data. Read the table at your temperature, not at 0°C, and size the room from that line. Treat all capacity figures as what they are: catalog sample data for reference. The exact specification of the unit you buy — including its dimensions, which the two-stage tables do not list — is fixed in the contract, not in the catalog.
How to order Ordering a KLDPL comes down to five inputs. First, the evaporating temperature — the deep temperature your room must hold, -40°C or below. Second, the cooling load at that temperature — calculated at the target temperature, not at 0°C. Third, the cooling method: air-cooled FL or water-cooled SL, decided by the site the same way as for any other unit. Fourth, the refrigerant: R22 or R404A. Fifth, the power supply on site. With those five, we match the model — from S4T-5.2 up to S6F-30.2 — and confirm the final specification in the contract. To start, send your room temperature, cooling load and cooling method through the inquiry form. Yiwu Ruluan Trading will come back with the matching KLDPL model and a quotation. No prices, lead times or certifications are listed on this page because the catalog does not give them; they are confirmed case by case, in writing, before you order.