COOLEST SL water-cooled condensing unit with BITZER semi-hermetic piston compressor
COOLEST water-cooled condensing unit with BITZER piston compressor
Water-Cooled Condensing Units

SL Series Bitzer Water-Cooled Piston Condensing Unit

Water-cooled condensing unit on the original German BITZER semi-hermetic piston compressor, for rooms from 12.5°C to -40°C. R22/R404A, 380V/3P/50Hz, models 2HES-2(Y)SL to 4NES-20(Y)SL and low-temperature KLPL-SL models. For sites with water on hand and no room for an outdoor condenser.

Specifications

Compressor
BITZER semi-hermetic piston compressor, original German
Series
SL, water-cooled (medium/high and medium/low versions)
Evaporating temperature
12.5°C to -25°C (medium/high); -5°C to -40°C (medium/low)
Refrigerant
R22 / R404A (Y models: R404A)
Power supply
380V / 3-phase / 50Hz
Model range
2HES-2(Y)SL to 4NES-20(Y)SL (medium/high)
Cooling capacity, 2HES-2 at 0°C, R22
5,060 W (catalog sample data)
Cooling capacity, 4NES-20 at 0°C, R22
47,200 W (catalog sample data)
Condenser
Water-cooled shell-and-tube condenser, no fan
Dimensions, 2HES-2
708 × 500 × 610 mm (27.9 × 19.7 × 24.0 in)
Standard configuration
Liquid reservoir, oil separator, suction accumulator, filter, sight glass, solenoid valve, pressure controller, gauges
Needs on site
Water supply and drainage (confirm before ordering)
The SL series is COOLEST's water-cooled condensing unit built on the original German BITZER semi-hermetic piston compressor, for rooms from 12.5°C down to -40°C. It runs on R22 or R404A at 380V/3P/50Hz, with medium/high models from 2HES-2(Y)SL to 4NES-20(Y)SL and low-temperature KLPL-SL versions. If your site has water on hand and no good place for an outdoor condenser, start here.
Who the SL fits, and who should look elsewhere The SL is for buyers whose site decides the cooling method for them. A cold room in a sealed plant room, a basement store, or a building where the condenser cannot sit outdoors — these are water-cooled jobs, because an air-cooled condenser in a sealed room recycles its own hot air and the room temperature drifts upward on the hottest days. The SL covers the same temperature ranges as the air-cooled piston series: 12.5°C to -25°C for medium/high-temperature rooms, and -5°C to -40°C for the low-temperature versions. A chilled store at 0°C is served by the smallest medium/high model, the 2HES-2, delivering 5,060 W at 0°C evaporating temperature on R22 (catalog sample data); the range runs up to the 4NES-20 at 47,200 W at the same temperature. Two buyers should not start here. If the site has open air and room for an outdoor condenser, the air-cooled KLPH or KLPL series is the simpler install — no water, no drainage, no second system to maintain. And if there is no water supply or drainage at the plant room at all, the SL cannot run there: water is not an accessory for this unit, it is the cooling medium. Confirm the water question before ordering, not during installation, when running a new water line is the most expensive possible moment to discover it.
What is inside, and how the numbers map to the job At the centre is the original German BITZER semi-hermetic piston compressor — the same machine as the air-cooled piston series, with accessories imported or from well-known domestic brands. The difference is the condenser: a water-cooled shell-and-tube condenser replaces the fan coil entirely, so there is no fan table for this series and no large airflow to provide. That is why the smallest unit is so compact: the 2HES-2 measures 708 × 500 × 610 mm, small enough for a tight plant room. The build follows the same pattern as the rest of the piston series — small vibration, low noise, compact structure, high reliability — and the same standard configuration: liquid reservoir, oil separator, suction accumulator, filter, sight glass, solenoid valve, pressure controller, high and low pressure gauges, discharge muffler, pipe interface valves, connection box and steel frame. The same model can run on R22 or R404A — Y models are the R404A versions — and power is 380V/3P/50Hz across the series. The catalog gives no water-consumption figures for the SL, and this page invents none: how much water the unit uses depends on the water temperature and the load, and it is confirmed with the supplier for the actual site. Treat the capacity figures as what they are: catalog sample data for reference. The exact specification of the unit you buy is fixed in the contract, not in the catalog.
How to order Ordering an SL comes down to five inputs. First, the evaporating temperature — the temperature your room must hold. Second, the cooling load at that temperature — or the room size, what goes in it, and the target temperature. Third, the refrigerant: R22 or R404A. Fourth, the power supply on site. Fifth, and specific to this series: the water — is there a supply and a drain at the plant room, and what is the water temperature? With those five, we match the model and confirm the final specification in the contract. To start, send your room temperature, cooling load and water situation through the inquiry form. Yiwu Ruluan Trading will come back with the matching SL model and a quotation. No prices, lead times or certifications are listed on this page because the catalog does not give them; they are confirmed case by case, in writing, before you order.