Every COOLEST unit in the catalog runs on R22 or R404A, and the choice is written into the model code: a Y in the model means R404A, and no Y means R22. The same model covers both refrigerants, and the capacity differs only slightly between them — the KLPH 2KES-05 gives 2,960 W at 0°C on R22 and 2,920 W on R404A, both catalog sample data. So the refrigerant rarely changes which unit you buy. What it does change is the exact model code you order, the refrigerant available in your market, and the rules that apply to it there. Confirm those three things before ordering. This guide is for buyers ordering a COOLEST unit who have not yet fixed the refrigerant. It will not help you if the refrigerant is already fixed by an existing plant — then the model code follows from it, and the remaining question is the model, not the refrigerant.
The letter that changes the order
A buyer ordered a KLPH unit by reading the model off a quotation: KLPH 2KES-05(Y)FL. The unit arrived, the installer charged it, and the system ran — on R404A, because the Y in the model means R404A. The buyer's existing plant ran on R22, and the new unit's refrigerant did not match the stock, the procedures, or the service routine the site already used. Nothing was broken and nothing was wrong with the unit; the order had simply been placed with a letter in it that nobody had read. The fix was a re-order and a month's delay.
That is the normal shape of this mistake. The refrigerant decision hides inside the model code, and buyers who order by model number alone can order the wrong refrigerant without noticing. The catalog is clear about the code: Y means R404A, and no Y means R22. The same model can use R404A or R22, and the product range is complete in both. The decision is small, it is written in one letter, and it is easy to get wrong by not reading it.
Why the catalog lists both, and what actually differs
Start with what the catalog does say, because it settles most of the question. The model code is KL plus the parallel count, the compressor type, the temperature family, the compressor model, then Y for R404A or nothing for R22, then the cooling method — FL for air-cooled, FLV for the V-type box, SL for water-cooled. Every series in the catalog is listed both ways: the capacity tables print R22 and R404A side by side for the same models, at the same evaporating temperatures, on the same 380V/3P/50Hz power supply. The two refrigerants are not two different product lines; they are two versions of the same line, and the buyer picks one.
What actually differs is small but real. The capacity differs slightly between the two refrigerants at the same temperature: the KLPH 2KES-05 gives 2,960 W at 0°C on R22 and 2,920 W on R404A, and the pattern holds across the tables — the numbers are close, and neither refrigerant is systematically far ahead. The power input differs slightly too, in the same direction. That means the refrigerant choice almost never changes the model: a unit sized for R22 will be the same model sized for R404A, with a capacity difference of a few percent that the sizing margin absorbs. What differs more is outside the catalog: whether R22 or R404A is available in the buyer's market, what it costs there, and what rules apply to it there. The catalog gives no prices and no regulatory guidance, and neither does this guide — those are market facts, and they change by place and by year.
The evidence gap is the market itself. Most buyers choosing a refrigerant know their own site — what the existing plant runs on, what the local supplier stocks, what the service team is used to — but have not checked whether that refrigerant is the right choice for a new unit in their market. The buyer with an existing R22 plant has a strong reason to stay on R22: same stock, same procedures, same service routine. The buyer with a new plant has a free choice, and should make it on availability and rules, not on habit. Either way, the choice should be made before the model code is written down, because the model code is where the choice becomes an order.
The decision, in three confirmations
Confirm the existing plant first. If the site already runs refrigeration equipment, what refrigerant does it use? Matching it means one stock, one set of procedures, and one service routine. Mixing refrigerants across a site means separate stock and separate procedures for the sake of one new unit, and that cost lasts longer than the unit. If there is no existing plant, this confirmation is skipped — and the next two decide instead.
Confirm availability and rules in your market second. Is R22 available from the local supplier, and at what price? Is R404A? Do local rules restrict either one for new installations, and do they change the paperwork? This guide states no rule for any market, because the rules differ by place and change over time — confirm them with the supplier and, if needed, with the local authority, before ordering. A refrigerant that is cheap and available in one market can be restricted or expensive in another, and the catalog cannot tell you which market you are in.
Confirm the model code third. Once the refrigerant is chosen, write the model code with the letter in it or out of it: Y for R404A, no Y for R22. Read the code back before the order goes in — KLPH 2KES-05(Y)FL is R404A, KLPH 2KES-05FL is R22 — and check it against the quotation. The difference is one letter, and it is the whole decision. If the quotation and the order disagree on that letter, stop and ask, because the unit that arrives will follow the code, not the conversation.
Different buyers land in different places. A buyer extending an existing R22 plant will usually land on R22: matching the site is worth more than any small capacity difference. A buyer building a new plant will weigh availability and rules, and will often land on R404A — or on R22, where it remains available and permitted. A distributor stocking for resale should stock the refrigerant the local installers ask for, and should know that the Y in the model code is the difference between the two shelf items.
What can go wrong, and what this guide does not cover
Four mistakes account for most of the trouble. The first is ordering by model number without reading the Y — the mistake this guide opened with, and the easiest to avoid by reading the code back. The second is assuming the capacity is identical: it is close, not identical, and a unit sized exactly to the limit on R22 may be a few percent short on R404A. Size with margin, and the difference disappears. The third is assuming the rules are the same everywhere: a refrigerant permitted for new installations in one market may be restricted in another, and the time to discover that is before ordering, not at commissioning. The fourth is treating catalog figures as guarantees. The catalog says so itself: sample data is for reference only, designs may change without notice, and detailed specifications are fixed in the contract. Use the tables to shortlist, not to promise.
There are also boundaries this guide does not cross. It does not compare refrigerants beyond R22 and R404A, because those are the two the catalog offers. It does not give prices, availability or regulatory dates for any market, because the catalog gives none and this guide invents nothing. It does not cover the cooling method, the temperature range, or the compressor type — each has its own guide. And it does not tell you which refrigerant is better in general, because there is no general answer: the answer is the refrigerant that matches your site, your market and your rules.
Your next step
Write down three things before you order. One: the refrigerant your existing plant runs on, if there is one. Two: which refrigerants are available in your market, and whether any rule restricts either one for a new installation. Three: the model code, with the Y in it or out of it, read back against the quotation. Then send the room temperature, the cooling load and the refrigerant through the inquiry form, and ask for the matching model with a quotation. Confirm the letter first; the model choice takes minutes once it is settled, and it takes weeks to undo if the letter was wrong.